Low speed large capacity centrifuge overview:
Low speed centrifugation technology for large capacity centrifuge is a new technology based on the state of particles in a suitable place in the centrifugal began. Different density, size or shape of the settlement of particles in a centrifugal place different, so a roughly spherical non homogeneous mixture, can use the centrifugal method to separation, the centrifuge is in order to further study the biological chemistry, separation of large quantities of substances. Such as collecting cells from the plasma, parting, parting the purified preparation of DNA and protein molecules, and separation of the virus and the large range of Escherichia coli, strict cellular components, such as nuclear protein particles. Low speed large capacity centrifuge using brushless DC motor, microcomputer control, with RCF automatic. With a variety of program maintenance. Operation is complex, with automatic balancing function.
Low speed large capacity centrifuge main technical parameters:
1: use AC 220V50HZ power supply
2 machine power: 600W
3 speed: 5000 rpm adjustable
4 centrifugal capacity: 4 x 250ml, 8 x 50ml, 36 x 10ml, 24 x 10ml, 4 x 500ml
5 the relative centripetal force: 4390xg
Low speed large capacity centrifuge use:
First of all, the low speed large capacity centrifuge with centrifuge tube in need parting materials, were inserted into the centrifugal head hole, each quality tube plus material centrifugal must fundamental equal, close the cover, a power supply is switched on, press the select key, choose what you need speed and work - amounting to time, and then press accreditation key to stop the confirmation, and then press the start button, at this time to enter the working state of the centrifuge. When arrived at the set working time will automatically alarm.
Low speed large capacity centrifuge note:
1: it is prohibited to all kinds of liquids or other debris into the centrifugal studio. Otherwise the return damaged host.
2: the instrument shell should be properly grounded, so as to avoid the machine damp impact and unexpected attack.
3: please don't open the upper cover the centrifugal head when running at high speed.
4: select accept errors will automatically alarm. Prompts you to select accept
Maintenance and accessories:
In the use of the centrifuge as found from the heart of eccentric, please knowledgeable personnel it, the first to open the bottom cover, check the motor three pillars can offset. Stop adjustment can be.