Automatic centrifuge with ordinary centrifuge advantage different hat

Other information about automatic decapping centrifuge and ordinary centrifuge differences please visit http://www.shlxj.com.cn/.

Automatic centrifuge to hat practice laboratory centrifuges, used throughout the clinical medicine, biochemistry, immunology, blood, medicine and other scientific research education and spend some, also known as automatic decapping centrifuge vacuum vessel special hat centrifuge. Automatic decapping centrifuge and usually advantage difference lies in the centrifuge:
(1) in the process of the initiative to take off the cover of the centrifugal vacuum vessel, road work power.
(2) instead of manual hat, avoid touch the body kit.
Automatic decapping centrifuge equipment note:
(1) the table begged solid and smooth, avoid hat centrifuges at work or mobile attack vibration instrument.
(2) power supply with independent ground, put a stop to the zero line and the ground wire sharing, avoid the shock of wounding.
(3) the hat around the centrifuge should be no corrosive gas and electromagnetic disturb, avoid instrument outer protective layer, premature failure and annoyance to the electrical components.
(4) the hat centrifuge placed degree, ensure the four rubber machine feet evenly force.
Automatic decapping centrifuge use code:
A centrifuge. The hat in after centrifugal out back to upside down on the bench, dry cavity residual water, cover is in the open state of the centrifuge.
Two. The back cover is placed in the centrifuge on the platform, or placed in the experimental stage, never do not tighten the floating in the back, because once the false start, back cover will fly out, constitute the trouble!
Three. The back cover in after tightening must touch the back and turn the cover between any gap with your fingers, such as gaps to unscrew the ab initio tighten until the confession, no gap can start centrifuge.
Four. Automatic decapping centrifuge during centrifugation, the operator does not score isolation scheming room, once the onset of abnormal situation the operator can not power off (POWER), according to STOP.
Five. Do not use fake centrifugal to make the tube, shall not use the aging, deformation, crack, substandard centrifugal tube.
Six. During the holidays and night after all the use of a centrifuge staff necessary routine security checks can go ahead.
Seven. Automatic decapping centrifuge machine defects in attack instrument application process, component damage situation should be promptly and US manufacturers contact, must not open instrument.